Network protocol info
Desc: Network protocol info
File: protocol.txt
Date: 14 July 2003
Auth: Russell Kroll
This protocol primarily runs over TCP, but there is some lingering
support for UDP. UDP support may be removed completely if there is no
interest. All clients shipped with the package use upsclient and
therefore TCP exclusively.
As of May 2002, this protocol now has an official port number from IANA,
which is 3493. The old number (3305) was a relic of the original code's
ancestry, and conflicted with other services. Version 0.50.0 and up
use 3493 by default.
============================================================================
New commands (April 2003)
============================================================================
These commands were added to support the new long variable names. They
do not recognize the older names, and will not perform any sort of
"mapping". If you need to do something with an old variable name, use
the older commands below.
The big difference to note here is that the notion of "@upsname" is
gone. The upsname is now a required part of many commands, and there is
no "default" UPS for any of these new commands. This was done to remove
ambiguity and to clean up a lot of ugly code in the server.
Multi-word elements are contained within "quotes" for easier parsing.
Embedded quotes are escaped with backslashes. Embedded backslashes are
also escaped by representing them as \\. This protocol is intended to
be interpreted with parseconf or something similar.
GET
===
Retrieve a single response from the server. This is the only new
command which will work over UDP.
Possible sub-commands:
NUMLOGINS
---------
Form: GET NUMLOGINS <upsname>
GET NUMLOGINS su700
Response: NUMLOGINS <upsname> <value>
NUMLOGINS su700 1
<value> is the number of clients which have done LOGIN for this UPS.
This is used by the master upsmon to determine how many clients are
still connected when starting the shutdown process.
This replaces the old "REQ NUMLOGINS" command.
UPSDESC
-------
Form: GET UPSDESC <upsname>
GET UPSDESC su700
Response: UPSDESC <upsname> "<description>"
UPSDESC su700 "Development box"
<description> is the value of "desc=" from ups.conf for this UPS. If it
is not set, upsd will return "Unavailable".
This can be used to provide human-readable descriptions instead of a
cryptic "upsname@hostname" string.
VAR
---
Form: GET VAR <upsname> <varname>
GET VAR su700 ups.status
Response: VAR <upsname> <varname> "<value>"
VAR su700 ups.status "OL"
This replaces the old "REQ" command.
TYPE
----
Form: GET TYPE <upsname> <varname>
GET TYPE su700 input.transfer.low
Response: TYPE <upsname> <varname> <type>...
TYPE su700 input.transfer.low ENUM
<type> can be several values, and multiple words may be returned:
RW - this variable may be set to another value with SET
ENUM - an enumerated type, which supports a few specific values
STRING:n - this is a string of maximum length n
ENUM and STRING are usually associated with RW, but not always.
This replaces the old "VARTYPE" command.
DESC
----
Form: GET DESC <upsname> <varname>
GET DESC su700 ups.status
Response: DESC <upsname> <varname> "<description>"
DESC su700 ups.status "UPS status"
<description> is a string that gives a brief explanation of the named
variable. upsd may return "Unavailable" if the file which provides this
description is not installed.
Different versions of this file may be used in some situations to
provide for localization and internationalization.
This replaces the old "VARDESC" command.
CMDDESC
-------
Form: GET CMDDESC <upsname> <cmdname>
GET CMDDESC su700 load.on
Response: CMDDESC <upsname> <cmdname> "<description>"
CMDDESC su700 load.on "Turn on the load immediately"
This is like DESC above, but it applies to the instant commands.
This replaces the old "INSTCMDDESC" command.
LIST
====
The LIST functions all share a common container format. They will
return "BEGIN LIST" and then repeat the initial query. The list then
follows, with as many lines are necessary to convey it. "END LIST" with
the initial query attached then follows.
The formatting may seem a bit redundant, but it makes a different form
of client possible. You can send a LIST query and then go off and wait
for it to get back to you. When it arrives, you don't need complicated
state machines to remember which list is which.
UPS
---
Form: LIST UPS
Response: BEGIN LIST UPS
UPS <upsname> "<description>"
...
END LIST UPS
BEGIN LIST UPS
UPS su700 "Development box"
END LIST UPS
<upsname> is a name from ups.conf, and <description> is the value of
desc= from ups.conf, if available. It will be set to "Unavailable"
otherwise.
This can be used to determine what values of <upsname> are valid before
calling other functions on the server. This is also a good way to
handle situations where a single upsd supports multiple drivers.
Clients which perform a UPS discovery process may find this useful.
VAR
---
Form: LIST VAR <upsname>
LIST VAR su700
Response: BEGIN LIST VAR <upsname>
VAR <upsname> <varname> "<value>"
...
END LIST VAR <upsname>
BEGIN LIST VAR su700
VAR su700 ups.mfr "APC"
VAR su700 ups.mfr.date "10/17/96"
...
END LIST VAR su700
This replaces the old "LISTVARS" command.
RW
--
Form: LIST RW <upsname>
LIST RW su700
Response: BEGIN LIST RW <upsname>
RW <upsname> <varname> "<value>"
...
END LIST RW <upsname>
BEGIN LIST RW su700
RW su700 output.voltage.target.battery "115"
RW su700 ups.delay.shutdown "020"
...
END LIST RW su700
This replaces the old "LISTRW" command.
CMD
---
Form: LIST CMD <upsname>
LIST CMD su700
Response: BEGIN LIST CMD <upsname>
CMD <upsname> <cmdname>
...
END LIST CMD <cmdname>
BEGIN LIST CMD su700
CMD su700 load.on
CMD su700 test.panel.start
...
END LIST CMD su700
This replaces the old "LISTINSTCMD" command.
ENUM
----
Form: LIST ENUM <upsname> <varname>
LIST ENUM su700 input.transfer.low
Response: BEGIN LIST ENUM <upsname> <varname>
ENUM <upsname> <varname> "<value>"
...
END LIST ENUM <upsname> <varname>
BEGIN LIST ENUM su700 input.transfer.low
ENUM su700 input.transfer.low "103"
ENUM su700 input.transfer.low "100"
...
END LIST ENUM su700 input.transfer.low
This replaces the old "ENUM" command.
Note: this does not support the old "SELECTED" notation. You must
request the current value separately.
============================================================================
Reworked commands
============================================================================
These commands have new argument sets that work with the new variable
names. Their older counterparts still exist, and will be used when
necessary for compatibility.
SET
---
Form: SET VAR <upsname> <varname> "<value>"
SET VAR su700 ups.id "My UPS"
INSTCMD
-------
Form: INSTCMD <upsname> <cmdname>
INSTCMD su700 test.panel.start
============================================================================
Older commands
============================================================================
These commands continue to be supported for backwards compatibility.
While the drivers are actually using the newer variable names
("ups.status" instead of STATUS), upsd will internally convert when
necessary.
The commands which use the old variable names will be going away after
the 1.x series, so you should upgrade any clients that are using them.
LISTVARS
========
Form: LISTVARS [<upsname>]
upsname is an identifier given to a UPS on a host. These are specified
in the ups.conf. If it is not specified, the server will refer to the
first entry from that file.
Returns: VARS <varlist>
Returns: VARS @<upsname> <varlist> (when upsname specified)
<varlist> is a space delimited list of all possible variables that
the server process knows about for this UPS.
Requires: MONITOR access
* Obsolete: switch to "LIST VAR".
REQ
===
Form: REQ]
<varname> is a variable name returned by LISTVARS or a reserved word:
- Reserved words:
NUMLOGINS - Number of systems currently monitoring this UPS
(incremented by LOGIN commands from authorized clients)
<upsname> is an identifier as seen above with LISTVARS.
Returns: ANS <varname> <value>
Returns: ANS (when upsname specified)
<varname> is the variable you requested, repeated just to be sure
<value> is the current value as the server knows it
*** Old versions of upsd also have a few special responses for <value>:
UNKNOWN
- upsd doesn't recognize this variable.
Replaced with "ERR VAR-UNKNOWN".
NOT-SUPPORTED
- this UPS driver doesn't gather data for this variable
Replaced with "ERR VAR-NOT-SUPPORTED".
DATA-STALE
- the server hasn't gotten an update for this data recently
Replaced with "ERR DATA-STALE".
Requires: MONITOR access
* Obsolete: switch to "GET VAR".
LISTRW
======
Form: LISTRW [<upsname>]
Returns: RW <read-write variable list>
RW @<upsname> <read-write variable list> (when upsname specified)
Requires: MONITOR access
Lists all variables that allow modification of their values within the
driver.
* Obsolete - switch to "LIST RW".
VARTYPE
=======
Form: VARTYPE]
Returns: TYPE <vartype> <extravalue>
Requires: MONITOR access
<vartype> is one of ENUM or STRING.
ENUM: Enumerated type, <extravalue> is how many possibilities exist
STRING: Character string, <extravalue> is how long it may be
Lists the type of a read-write variable.
* Obsolete - switch to "GET TYPE".
VARDESC
=======
Form: VARDESC <varname>
Returns: DESC "<variable description>"
Requires: MONITOR access
<variable description> is a short explanation of what a variable means.
* Obsolete - switch to "GET DESC".
ENUM
====
Form: ENUM]
Returns: multi-line return:
ENUM <varname>
OPTION "<optval>" [SELECTED] may repeat multiple times
END
Requires: MONITOR access
<optval> is a valid option for <varname>. SELECTED will be included if
<varname> is currently set to <optval> in the hardware.
Shows the possible values for an enumerated type R/W variable.
* Obsolete - switch to "LIST ENUM".
INSTCMD
=======
Form: INSTCMD]
Requires: "INSTCMD" action granted in upsd.users
"<command>" instcmd granted in upsd.users
<command> is an instant command name. See LISTINSTCMD and shared.h.
* Obsolete - switch to new form: "INSTCMD <upsname> <cmdname>"
LISTINSTCMD
===========
Form: LISTINSTCMD [<upsname>]
Returns: INSTCMDS [@<upsname>] <cmd1> <cmd2> ... <cmdn>
Requires: MONITOR access
Shows all the instant commands available on a given UPS.
* Obsolete - switch to "LIST CMD"
INSTCMDDESC
===========
Form: INSTCMDDESC <cmdname>
Requires: MONITOR access
Returns: DESC "<description>"
Shows the description for a given instant command suitable for showing
to users.
* Obsolete - switch to "LIST CMDDESC"
SET
===
Form: SET
<value> is an acceptable sequence for the variable <varname>.
Requires: "SET" action granted in upsd.users
Sets the R/W variable <varname> to <value>, assuming it is allowed.
* Obsolete - switch to new form: "SET VAR <upsname> <varname> <value>".
============================================================================
Unchanged commands
============================================================================
These commands are not affected by the variable name change.
LOGOUT
======
Form: LOGOUT
Returns: OK Goodbye (recent versions)
TCP mode only. Used to disconnect gracefully from the server.
Older versions just said "Goodbye...".
LOGIN
=====
Form: LOGIN <upsname>
Returns: OK (upon success)
or various errors
Requires: "upsmon slave" or "upsmon master" in upsd.users
Use this to log the fact that a system is drawing power from this UPS.
The upsmon master will wait until the count of attached systems reaches
1 - itself. This allows the slaves to shut down first.
NOTE: You probably shouldn't send this command unless you are upsmon,
or a upsmon replacement.
MASTER
======
Form: MASTER <upsname>
Returns: OK (upon success)
or various errors
Requires: "upsmon master" in upsd.users
This function doesn't do much by itself. It is used by upsmon to make
sure that master-level functions like FSD are available if necessary.
FSD
===
Form: FSD <upsname>
Returns: OK FSD-SET (success)
or various errors
Requires: "upsmon master" in upsd.users
or "FSD" action granted in upsd.users
upsmon in master mode is the primary user of this function. It sets this
"forced shutdown" flag on any UPS when it plans to power it off. This is
done so that slave systems will know about it and shut down before the
power disappears.
Setting this flag makes "FSD" appear in a STATUS request for this UPS.
Finding "FSD" in a status request should be treated just like a "OB LB".
It should be noted that FSD is currently a latch - once set, there is
no way to clear it short of restarting upsd or dropping then re-adding
it in the ups.conf. This may cause issues when upsd is running on a
system that is not shut down due to the UPS event.
PASSWORD
========
Form: PASSWORD <password>
Returns: OK (upon success)
or various errors
Requires: BASE or higher access
Sets the password associated with a connection. Used for later
authentication for commands that require it.
USERNAME
========
Form: USERNAME <username>
Returns: OK (upon success)
or various errors
Requires: BASE or higher access
Sets the username associated with a connection. This is also used for
authentication, specifically in conjunction with the upsd.users file.
STARTTLS
========
Form: STARTTLS
Requires: TCP connection (impossible over UDP)
Returns: OK STARTTLS
or various errors
This tells upsd to switch to TLS mode internally, so all future
communications will be encrypted. You must also change to TLS mode in
the client after receiving the OK, or the connection will be useless.
Other commands
==============
HELP - lists the commands supported by this server
VER - shows the version of the server currently in use
These two are not intended to be used directly by programs. Humans can
make use of this program by using telnet for TCP or netcat for UDP. Try
either "telnet localhost 3493" for TCP or "nc -u localhost 3493" for UDP
and it should talk to you.
Error responses
===============
This list is not yet in sync with the changes that appeared in 1.3.
ERR <message> [<extra>...]
<message> is always one element; it never contains spaces. This may
be used to allow additional information (<extra>) in the future.
ACCESS-DENIED
- The client's host and/or authentication details (username, password)
are not sufficient to execute the requested command.
UNKNOWN-UPS
- The UPS specified in the request is not known to upsd. This usually
means that it didn't match anything in ups.conf.
VAR-NOT-SUPPORTED
- The specified UPS doesn't support the variable in the request.
This is also sent for unrecognized variables which are in a space
which is handled by upsd, such as server.*.
CMD-NOT-SUPPORTED
- The specified UPS doesn't support the instant command in the request.
INVALID-ARGUMENT
- The client sent an argument to a command which is not recognized or
is otherwise invalid in this context. This is typically caused by
sending a valid command like GET with an invalid subcommand.
INSTCMD-FAILED
- upsd failed to deliver the instant command request to the driver.
No further information is available to the client. This typically
indicates a dead or broken driver.
SET-FAILED
- upsd failed to deliver the set request to the driver. This is
just like INSTCMD-FAILED above.
READONLY
- The requested variable in a SET command is not writable.
TOO-LONG
- The requested value in a SET command is too long.
FEATURE-NOT-SUPPORTED
- This instance of upsd does not support the requested feature. This
is only used for TLS/SSL mode (STARTTLS) at the moment.
FEATURE-NOT-CONFIGURED
- This instance of upsd hasn't been configured properly to allow the
requested feature to operate. This is also limited to STARTTLS for
now.
ALREADY-SSL-MODE
- TLS/SSL mode is already enabled on this connection, so upsd can't
start it again.
DRIVER-NOT-CONNECTED
- upsd can't perform the requested command, since the driver for that
UPS is not connected. This usually means that the driver is not
running, or if it is, the ups.conf is misconfigured.
DATA-STALE
- upsd is connected to the driver for the UPS, but that driver isn't
providing regular updates or has specifically marked the data
as stale. upsd refuses to provide variables on stale units to avoid
false readings.
This generally means that the driver is running, but it has lost
communications with the hardware. Check the physical connection
to the equipment.
ALREADY-LOGGED-IN
- The client already sent LOGIN for a UPS and can't do it again.
There is presently a limit of one LOGIN record per connection.
INVALID-PASSWORD
- The client sent an invalid PASSWORD - perhaps an empty one.
ALREADY-SET-PASSWORD
- The client already set a PASSWORD and can't set another. This also
should never happen with normal NUT clients.
INVALID-USERNAME
- The client sent an invalid USERNAME.
ALREADY-SET-USERNAME
- The client has already set a USERNAME, and can't set another. This
should never happen with normal NUT clients.
USERNAME-REQUIRED
- The requested command requires a username for authentication,
but the client hasn't set one.
PASSWORD-REQUIRED
- The requested command requires a passname for authentication,
but the client hasn't set one.
UNKNOWN-COMMAND
- upsd doesn't recognize the requested command.
This can be useful for backwards compatibility with older versions
of upsd. Some NUT clients will try GET and fall back on REQ after
receiving this response.
INVALID-VALUE
- The value specified in the request is not valid. This usually
applies to a SET of an ENUM type which is using a value which is
not in the list of allowed values.
Old error messages
==================
These are only used by the compatibility functions in upsd for the old
variable/command names and (naturally) by older versions of upsd.
VAR-UNKNOWN
- The client requested an unrecognized variable. This only applies
to old variable names, as there is a finite list of them.
UNKNOWN-TYPE
- The client requested VARTYPE of something that is not recognized
by upsd. This should never happen.
UNKNOWN-INSTCMD
- The client tried to start an unrecognized command. This is also
only for old command names, as they also have a finite list.
MISSING-ARGUMENT
- The client's request is missing at least one argument. This is
used for compatibility with older clients.
Future ideas
============
Dense lists
-----------
The LIST commands may be given the ability to handle options some day.
For example, "LIST VARS <ups> +DESC" would return the current value
like now, but it would also append the description of that variable.
Command status
--------------
After sending an INSTCMD or SET, a client will eventually be able to
poll to see whether it was completed successfully by the driver.
|